Most controllers that do not have a hardware switch have a Disable RT Startup App checkbox in Measurement and Automation Explorer. #Disable realtimes sign in manual#
For more information about using these hardware dip switches refer to the product manual of your device.
For PXI controllers, make sure the LabVIEW RT setup menu in the BIOS has Use Hardware Switch selected for Disable Startup VI?. PXI controllers label the switch "Disable Statup VI". Older model FieldPoint devices label this hardware switch "Disable VI".
Some cRIO controllers and the latest Compact FieldPoint controllers label this switch "NO APP". On some FieldPoint, CompactRIO and Real-Time PXI controllers there is a hardware switch on the device that will prevent VIs and executables from running on startup. If the 'Target destination directory' of the Build Specification was altered, then delete these files from the specified directory).
rtexe file (this is the default startup directory for RT PXI/cRIO Build Specifications. You can use any FTP client to navigate to ftp:///ni-rt/startup and delete the.
You can remove the executable from the /ni-rt/startup/ folder on VxWorks and PharLap Real-Time controllers. It may be helpful to reboot your controller into safe mode before performing these steps, as that will prevent any startup applications from running - this will however reset the IP address as well: Note that these are general steps you can take, and don't have a specific order. There are a few methods you can use to prevent an executable from running at startup.